| Make | Model | Problem | Solution | Added | Date |
| | | | |
| Found: 4551 |
| Philips | 21PV267 | Set produces audible noise in stand-by | Add a small LEBL (leading edge blanking) PCB, to avoid auto oscillation of transformer 5330 (or 5331). A modification letter is included with the lable PCB. This PCB is available with service nr. 4822 214 12173.
Since production week 9723 this circuit is | plamensl | 14-09-2004 |
| Philips | 21PV267 | Set produces audible noise in stand-by | Add a small LEBL (leading edge blanking) PCB, to avoid auto oscillation of transformer 5330 (or 5331). A modification letter is included with the LEBL PCB.
This PCB is available with service nr. 4822 214 12173. | plamensl | 14-09-2004 |
| Philips | 21PV267 | Spare part information | A repair kit , containing PULLEY SHAFT + WORM SHAFT (POS. 47+48) is delivered with codenumber 4822 310 10657.
This kit can be used for all TURBO- and ECO mechanisms ! | plamensl | 14-09-2004 |
| Philips | 21PV267 | Spare part information | If the lever inside the mains-switch is broken, the switch doesn't remain in the "ON" position.
Solution: replace the switch by a new one. Improved switches of a newer production range are on stock. (4822 276 13542) | plamensl | 14-09-2004 |
| Philips | 21PV267 | Spare part information | Sets produced from week 9608 until 9647
Motor holder with reverse prism included: In sets produced before week 9647 the reverse prism is a fixed part of the chassis and not available as a spare part. From week 9647 onwards a motor holder (pos.40) with | plamensl | 14-09-2004 |
| Philips | 21PV267 | Start up problems after replacing TS7352 | When TS7352 is replaced, it can happen that the set doesn't start up properly.
There are 2 possible solutions for this problem:
- use SGS type MTP3055E (4822 130 63726).
- In case of a motorola type MTP3055V (4822 130 60838), add a 22 uH coil solde | plamensl | 14-09-2004 |
| Philips | 21PV267/01 | Codenumber information | A new software version (PTCP2-7) is available for the control uP (IC 7801). Service codenumber is 4822 209 15271.
This new version is only used in the following sets:
14PV263/01, 14PV162/01, 14PV162/05, 14PV162/07, 14PV163/05, 14PV163/05H, 14PV263/01 | plamensl | 14-09-2004 |
| Philips | 21PV267/01 | Option code: 57260 | From week 02/97 onwards the option code is printed on the typesticker. Always use this code !
For early sets without this information on the typesticker, the option code is: 57260. | plamensl | 14-09-2004 |
| Philips | 21PV267/02 | New VPS IC SDA5642-6 (pos. 7840) | Since production week 9741 a new VPS IC pos. 7840 (SDA5642-6) is introduced in production.
This IC is not compatible with the previous one. When ordering, look at the printing on the IC !
Old: SDA 5642-5 - codenumber 4822 209 32728
New: SDA 5642- | plamensl | 14-09-2004 |
| Philips | 21PV267/02 | Option code: 56300 | From week 02/97 onwards the option code is printed on the typesticker. Always use this code !
For early sets without this information on the typesticker, the option code is: 57260. | plamensl | 14-09-2004 |
| Philips | 21PV287/39 | Codenumber information | A new software version (PTCP2-7) is available for the control uP (IC 7801). Service codenumber is 4822 209 15271.
This new version is only used in the following sets:
14PV263/01, 14PV162/01, 14PV162/05, 14PV162/07, 14PV163/05, 14PV163/05H, 14PV263/01 | plamensl | 14-09-2004 |
| Philips | 21PV288 | St/by only | IC7881 SAA5254 Txt proc chip faulty | plamensl | 14-09-2004 |
| Philips | 21PV288/05 | Dead - 4A fuse o/c, D6313/4 bridge rect s/c | R3344 2R 5w o/c due to C2328 470pf 2kv arcing behind chopper tr heatsink | plamensl | 14-09-2004 |
| Philips | 21PV320/05 | Hotel mode removal | Select CH38. Hold down Stop on R/C & Stop on TV for 5 secs until H- is displayed. | plamensl | 14-09-2004 |
| Philips | 21PV330/07 Delta 2000 | Dead - LOPTr s/c - blows again few hrs aft replacement | line dr trfmr relacement cured it | plamensl | 14-09-2004 |
| Philips | 21PV688 | Dead - safety res R3514 & 3592 o/c & D6524 s/c | Now tripping - TDA6107Q on crt base & FOP chip faulty | plamensl | 14-09-2004 |
| Philips | 21PV688 | dead, PSU not running | R3338 39R 0.25W o/c (discharge mains cap first!) | plamensl | 14-09-2004 |
| Philips | 21PV688 | int. shutting down after frame IC has been replaced | if replaced with later version 6 , also fit frame mof kit 4822 209 16781 | plamensl | 14-09-2004 |
| Philips | 21PV688 | No Video remote operation (TV sect ok) | Leave batts out of handset to discharge (several hours) | plamensl | 14-09-2004 |