Found: 4
Mitsubishi
25AV1BDS
dead/tripping led flashing
replace C702 1000µ 6.3v with 10µ & C955 2200µ 16v with 3300µ & do a reset (sw on whilst holding reset button in (near tuner)) & set up eeprom options
14-09-04
Mitsubishi
CT
25AV1BDS
Service mode & EEPROM settings
Switch on with mains switch and press service microswitch, select button 9 on the remote within 5secs. You will now be in the service mode. Use the buttons on the remote control for the following adjustments: * to toggle between adjustment displays 1 cancel; 2 increase adjustment code; 4 decrease data value; 6 increase data value; 8 decrease adjustment code; 9 adjustment mode on; 0 write to the eeprom( press this to write your changes to the eeprom) Here are the options- TUN 0; SAT 1; AUD 10; ATS 1; STD 1; SYS 1; AV1 2; EEX -; SPK 1; EEP -; ABG 02; A1 02;AL 00; ADK 15; MNP 70; TXT -; FFT 1; VOL 74;HYP 1; SCP 20; FMP 23. not all options appear to be available to some models. Adjustments in the VCJ mode will be in default mode and it will be necessary to observe display in order to set-up width height ew etc.
14-09-04
Mitsubishi
CT
25AV1BDS
EE3
Int blows LOPTr at sw on from cold & lack of height/int contrast from cold
C956 6.3V 470uF in 5V supply.
14-09-04
Mitsubishi
EE3 CT
25AV1BDS
Herringbone pattern, flashing lines etc with no pic for 5 minutes. Picture then slowly appears
C956 470uF 6.3V
14-09-04