Text preview for : ttt05-005.pdf part of RCA D52130 Large File 6 pare RAR Folder containing: Flow Charts, Tech Tips, Trouble Shooting Manuals, Updates, Module Training, and Symptom Fixes



Back to : RCA_CTC210-211_01.rar | Home

THOMSON TECHNICAL COMMUNICATION
HD Television

TechLine Troubleshooting Tip

TTT 05-005

The information contained herein is provided solely to assist in the diagnosis of the problem described. It is not intended as a modification or alteration of the product.
DATE: 10/25/2005 CHASSIS-MODEL: MMC101/102, CTC210/211, AND DTV306/307 TOPIC: X-ray Protect Components

XRP KITS - SEE CHART BELOW IMPORTANT : Replacement of any failed component supplied within the XPR kit requires the
replacement of ALL supplied kit parts. This is required to insure proper operation or the XPR circuitry. DO NOT replace individual parts supplied within this kit under any circumstances. 1. Install ALL supplied parts in the chassis (CR14900 Diode S/N 159429 is in all kits, see chart below for the values included in the kit you ordered to replace R14901,R14902, R14904, Q14901). 2. Conduct the XPR shutdown test as described in the Service Manual to verify proper XPR. Operation.

CHASSIS MMC101CC/CE MM101GBE MM101GCE MMC102A/G CTC210 CTC211 DTV306CB/GCB

Q14901 147665 50888-780 215496 15475-150

R14901 218494 40436-300 1/4W 1% 24.3K 249807 80437-750 1/4W 1% 30.1K

R14902 190469 11061-120 1/4W 1% 39.2K 190469 11061-120 1/4W 1% 39.2K

R14904 239019 30939-530 1/4W 5% 220K 175355 11059-750 1/4W 5% 300K 175355 11059-750 1/4W 5% 300K

KIT S/N 245682 251197 251199

215496 15475-150 151883 80437-740 1/4W 190469 11061-120 1% 27.4K 1/4W 1% 39.2K

250740 15563-390 228015 70431-300 1/4W 176500 50883-790 1% 11.3K 1/4W 1% 41.2K 250740 15563-390 228015 70431-300 1/4W 176500 50883-790 1% 11.3K 1/4W 1% 41.2K

175355 11059-750 1/4W 5% 300K 193067 70430-620 1/4W 5% 270K

251201

DTV307GA

251202

Product Safety Information
Product Safety information is contained in the appropriate Thomson Service Data covering models/chassis referenced herein. All specified Product Safety requirements and testing shall be complied with prior to returning equipment to the customer. Servicers who defeat safety features or fail to perform safety checks may be liable for any resulting damages and may expose themselves and others to possible injury.
First Edition First Printing Copyright 2005 Thomson Inc. Printed in U.S.A. Trademark(s) ® Registered Marca(s) Registrada(s)

THOMSON INC.